Fire extinguishers ''stop piro'' for extinguishing

THE BASIC CHARACTERISTIC OF THE FIREFIGHTING SET «STOP-PIRO»

''STOP-PIRO'' devices are applied for fire prevention. They contain a firefighter liquid «PPO/PPSR» which by activation of a pyrotechnic admixture (by explosion) is spread over a fire site. By applying «STOP-PIRO» devices, we obtain three basic important effects, first: at the action of explosion there is an increased consumption of oxygen at a fire site, second: by spreading more of ''PPO/PPSR'' at temperature of 3000C over the fire site, the phenomenon of thermolysis and of fire site refrigeration will be stronger, and third: «PPO/PPSR» is also used as a flame retardant at the fire site (cca: 10-15 minutes which makes impossible for fire to inflame again.

THE APPLIANCE OF THE FIREFIGHTING SET ''STOP-PIRO''

''STOP-PIRO'' devices are intended for firefighting of micro-macro fires in european classes A and B. They are used for preventive firefighting of local micro-initial fires in all motor vehicles. It is equally efficient for both motor firefighting and firefighting of travellers' space. Also, their appliance is recommended with all types of vehicles, as well as in closed spaces. 1 litre of ''PPO/PPSR'' extinguishes cca 8m3of space.
According to their appliance/usage, «STOP-PIRO» devices can be divided into two gropus:
  • FMD (firefighting mobile device,
  • FSD (firefighting stable device).
In both versions the identical firefighter liquid «STOP-PIRO» is used, as well as the pyrotechnic igniter. The pyrotechnic igniter contains 0,8 grams of pyrotechnic mixture, which is enough for the efficient spreading of firefighter liquid. Moreover, it is sufficiently harmless for its users.

ABOUT SERVICE

  • Control equipment must be performed each year (one year) to avoid possible mechanical damage
  • ''PPO / PPSR'' is monitored every five (5) years, and after ten (10) years is required replacement with new ones.
  • The pyrotechnics system is controlled once in a year - for the pyrotechnic mixture most important is that over time does not come into contact with moisture or liquid, which violates the correctness of fire apparatus.

FIREFIGHTER LIQUID ''PPO/PPSR'' FOR EXTERNAL USE

On the trail of the development of basic products, we came to the knowledge of the experimental phase to the outside - open fire''could be applied PPO / PPSR''in containers larger volume 50,100,200 liters or more through tanks, helicopters and GPS devices as well as aircraft (Canadair ).
This variant of the product would be designed for professional Fire Department in extinguishing external type, such as prevention against forest fires, fire building, etc.